COSMOSIL HILIC is a new column for hydrophilic interaction chromatography with Triazole bonded silica packing material. The hydrophilic interaction chromatography is a variation of normal phase chromatography where a polar stationary phase is used with a mobile phase which contains a high concentration of organic solvent and a low concentration of aqueous eluent. The main retention mechanism is the partitioning of the polar analytes between the polar stationary and the non-polar mobile phase. As it is also called "aqueous normal phase", the elution order is similar to that of normal phase and the sample elution is in the order of increasing hydrophilicity. Without using ion-pair reagent COSMOSIL HILIC retains highly polar analytes that would not be retained in reversed phase chromatography. It also shows a weak anion-exchange mechanism with the positively charged stationary phase, thus acidic compound is strongly retained.


Melamine analysis by COSMOSIL HILIC



Features of COSMOSIL HILIC

  • Retains highly polar compounds that would not be retained in C18 columns.
  • Ion-pair reagent is not required
  • Anion-exchange results in strong retention for acidic compounds.
  • Enhanced sensitivity in LC/MS
Comparison with Hydrophobicity
COSMOSIL HILIC can separate Glycine and Glycylglycine without ion-pair reagent. Although C18 column can separate
them with ion-pair reagents, there are some disadvantages such as column equilibration, preparation of mobile phase and column deterioration.


Material characteristics


Different interactions
The retention Mechanism of COSMOSIL HILIC is the combination of hydrophilic interaction and anion exchange, and the
retention can be controlled by changing the mobile phase.




Analysis data




Melamine analysis by COSMOSIL HILIC


Combination with C18 columns


Selection of mobile phase
Following are the recommended mobile phases for different samples.
Acetonitrile / Water = 90 / 10
Acetonitrile / 10mmol/l CH3COONH4 = 90 / 10
Acetonitrile / 10mmol/l CH3COONH4 = 70 / 30
Acetonitrile / 10mmol/l CH3COONH4 = 50 / 50
(not eluted) Acetonitrile / 10mmol/l Phosphatase buffer (pH7.0) = 50 / 50


COSMOSIL Chromatogram Index
COMSOSIL HILIC Chromatogram Index, which includes 154 chromatograms using COSMOSIL HILIC, is now available. This index is useful for optimizing analytical conditions for hydrophilic interaction chromatography.



COSMOSIL HILIC (PDF file 337KB)



COSMOSIL Chromatogram Index (PDF file 3.1MB)



Poster Presentation

HPLC 2008 (PDF file)
May 10-16, 2008
Baltimore, MD, USA
HPLC 2007 (PDF file)
June 17-21, 2007
Ghent, Belgium



Ordering information

Product name

Size

Code No.

COSMOSIL® HILIC Guard Column

4.6mml.D.x 10mm

07055-61

10mml.D.x 20mm

07058-31

20mmI.D. x 20mm 07854-91
20mmI.D. x 50mm 07873-41
28mmI.D. x 50mm 07874-31

COSMOSIL® HILIC Packed Column

1.0mml.D.x 150mm 07869-11
1.0mml.D.x 250mm 07870-71

2.0mml.D.x 50mm

07052-91

2.0mml.D.x 150mm

07054-71
2.0mml.D.x 250mm 07489-91

3.0mml.D.x 150mm

07871-61
3.0mml.D.x 250mm 07872-51

4.6mml.D.x 150mm

07056-51

4.6mml.D.x 250mm

07057-41

10mml.D.x 250mm

07059-21

20mml.D.x 250mm

07060-81
28mml.D.x 250mm 07875-21



 