COSMOSIL HILIC is a new column for hydrophilic interaction chromatography
with Triazole bonded silica packing material. The hydrophilic interaction
chromatography is a variation of normal phase chromatography where a polar
stationary phase is used with a mobile phase which contains a high concentration
of organic solvent and a low concentration of aqueous eluent. The main
retention mechanism is the partitioning of the polar analytes between the
polar stationary and the non-polar mobile phase. As it is also called "aqueous
normal phase", the elution order is similar to that of normal phase
and the sample elution is in the order of increasing hydrophilicity. Without
using ion-pair reagent COSMOSIL HILIC retains highly polar analytes that
would not be retained in reversed phase chromatography. It also shows a
weak anion-exchange mechanism with the positively charged stationary phase,
thus acidic compound is strongly retained. |
|
Melamine analysis by COSMOSIL HILIC |
Features of COSMOSIL HILIC
|
- Retains highly polar compounds that would not be retained in C18 columns.
- Ion-pair reagent is not required
- Anion-exchange results in strong retention for acidic compounds.
- Enhanced sensitivity in LC/MS
|
|
Comparison with Hydrophobicity
COSMOSIL HILIC can separate Glycine and Glycylglycine without ion-pair reagent. Although C18 column can separate
them with ion-pair reagents, there are some disadvantages such as column
equilibration, preparation of mobile phase and column deterioration. |
 |
Material characteristics |
 |
Different interactions |
The retention Mechanism of COSMOSIL HILIC is the combination of hydrophilic interaction and anion exchange, and the
retention can be controlled by changing the mobile phase. |
 |
 |
Analysis data |
 |
 |
 |
 |
Melamine analysis by COSMOSIL HILIC |
Combination with C18 columns |
 |
Selection of mobile phase |
| Following are the recommended mobile phases for different samples. |
Acetonitrile / Water = 90 / 10
Acetonitrile / 10mmol/l CH3COONH4 = 90 / 10
Acetonitrile / 10mmol/l CH3COONH4 = 70 / 30
Acetonitrile / 10mmol/l CH3COONH4 = 50 / 50
(not eluted) Acetonitrile / 10mmol/l Phosphatase buffer (pH7.0) = 50 / 50 |
COSMOSIL Chromatogram Index |
| COMSOSIL HILIC Chromatogram Index, which includes 154 chromatograms using
COSMOSIL HILIC, is now available. This index is useful for optimizing analytical
conditions for hydrophilic interaction chromatography. |

COSMOSIL HILIC (PDF file 337KB) |

COSMOSIL Chromatogram Index (PDF file 3.1MB) |
Poster Presentation
|
|
Ordering information
|
Product name |
Size |
Code No. |
COSMOSIL® HILIC Guard Column |
4.6mml.D.x 10mm |
07055-61 |
10mml.D.x 20mm |
07058-31 |
| 20mmI.D. x 20mm |
07854-91 |
| 20mmI.D. x 50mm |
07873-41 |
| 28mmI.D. x 50mm |
07874-31 |
COSMOSIL® HILIC Packed Column |
1.0mml.D.x 150mm |
07869-11 |
| 1.0mml.D.x 250mm |
07870-71 |
2.0mml.D.x 50mm |
07052-91 |
2.0mml.D.x 150mm |
07054-71 |
| 2.0mml.D.x 250mm |
07489-91 |
3.0mml.D.x 150mm |
07871-61 |
| 3.0mml.D.x 250mm |
07872-51 |
4.6mml.D.x 150mm |
07056-51 |
4.6mml.D.x 250mm |
07057-41 |
10mml.D.x 250mm |
07059-21 |
20mml.D.x 250mm |
07060-81 |
| 28mml.D.x 250mm |
07875-21 |
|
|
 |
| |
| (C)2008 Nacalai Tesque, Inc.