COSMOSIL C18-PAQ
Features
- Compatible with 100% water based mobile phase
- Suitable for hydrophilic compounds
Product Information
Column Specifications
Stable Performance
The figure shows the change of retention time for thymine with 100% aqueous mobile phase (20 mmol/l phosphate buffer pH7). The sample was analyzed 4 times (1 hour). Flow of mobile phase was then stopped for 1 hour. The sample was analyzed under the same condition again after 1 hour. The conventional C18 column showed change of retention time, but COSMOSIL 5C18-PAQ maintained stable retention time.
Stable performance under 100% aqueous conditions
Applications
Organic Acids
Condition | |
---|---|
Column Size | 4.6 mm I.D. x 250 mm |
Mobile Phase | 20mmol/l Phosphate buffer(pH2.5) |
Flow Rate | 1.0 ml/min |
Temperature | 30°C |
Detection | UV210nm |
Sample |
|
Nucleobases and Nucleosides
Condition | |
---|---|
Column Size | 4.6 mm I.D. x 150 mm |
Mobile Phase | 20mmol/l Phosphate buffer(pH7) |
Flow Rate | 1.0 ml/min |
Temperature | 30°C |
Detection | UV260nm |
Sample |
|
dNTP
Condition | |
---|---|
Column Size | 4.6 mm I.D. x 250 mm |
Mobile Phase | 20mmol/l Phosphate buffer(pH7) |
Flow Rate | 1.0 ml/min |
Temperature | 30°C |
Detection | UV260nm, 0.16AUFS |
Sample |
|
Catecholamines
Condition | |
---|---|
Column Size | 4.6 mm I.D. x 250 mm |
Mobile Phase | 20mmol/l Phosphate buffer(pH7.0) |
Flow Rate | 1.0 ml/min |
Temperature | 30°C |
Detection | UV270nm |
Sample |
|
Ascorbic Acid
Condition | |
---|---|
Column Size | 4.6 mm I.D. x 250 mm |
Mobile Phase | 20mmol/l Phosphoric Acid |
Flow Rate | 1.0 ml/min |
Temperature | 30°C |
Detection | UV245nm, 0.16AUFS |
Sample | L(+)-Ascorbic Acid [Vitamin C] (0.1µg) |
2-Phenylethyl glycosides
Condition | |
---|---|
Column Size | 4.6 mm I.D. x 150 mm |
Mobile Phase | Acetonitrile/Methanol/ H2O= 8/4/88 |
Flow Rate | 1.0 ml/min |
Temperature | 30°C |
Detection | UV210nm |
Sample |
|
Usage information
Column | 5 µm C18-PAQ | |||||||
---|---|---|---|---|---|---|---|---|
I.D. (mm) | 1.0 | 2.0 | 3.0 | 4.6 | 6.0 | 10.0 | 20.0 | 28.0 |
Washing method | 1. Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water. 2. (If you used a buffer, always do step 1 first!) Remove adsorbed compounds and fix unstable baselines by washing with methanol and/or THF. |
|||||||
Storage conditions | Short-term (up to a week): Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water. Long-term: Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. Then, replace the solvent with 70% methanol or acetonitrile : 30% water. In either case, tightly plug the column, and store in a cool and dry place. |
|||||||
Usable pH range | pH2~pH7.5 | |||||||
Max. pressure | 20MPa | 15MPa | ||||||
Temperature range | The maximum usable temperature is 60°C. However. for regular use, please use at a constant temperature between 20°C and 50°C. | |||||||
Usable solvents | Any solvent that will not dissolve the silica gel (such as alkaline solutions) or cleave the stationary phase (such as very acidic solutions) is usable. Note: For solvents with high viscosity, please watch the system pressure and keep it below 20 MPa. Also, please wash the column after using acidic mobile phases or solvents with high freezing points. |
|||||||
Other instructions | - Buffer concentration is usually sufficient at 0.005 - 0.02 mol/L. - Always filter mobile phases using a 0.5 µm or finer filter before use. |
Downloads
Brochure
COSMOSIL 5C18-PAQ (791 KB)
References
Reference list
Ordering Information
Analytical Column (Particle Size : 5 µm)
COSMOSIL 5C18-PAQ
Product Name | Size | Product No. | Price |
---|---|---|---|
COSMOSIL 5C18-PAQ Guard Column | |||
4.6 mm I.D. x 10 mm | 02484-91 | ||
10 mm I.D. x 20 mm | 34457-61 | ||
20 mm I.D. x 20 mm | 05803-11 | ||
20 mm I.D. x 50 mm | 05804-01 | ||
28 mm I.D. x 50 mm | 34455-81 | ||
COSMOSIL 5C18-PAQ Guard Cartridge Guard cartridge holder is required. |
4.6 mm l.D. x 10 mm | 19181-44 | |
COSMOSIL 5C18-PAQ Packed Column | |||
1.0 mm I.D. x 50 mm | 05792-61 | ||
1.0 mm I.D. x 150 mm | 05793-51 | ||
2.0 mm I.D. x 30 mm | 05878-51 | ||
2.0 mm I.D. x 50 mm | 05794-41 | ||
2.0 mm I.D. x 100 mm | 05470-71 | ||
2.0 mm I.D. x 150 mm | 34449-71 | ||
2.0 mm I.D. x 250 mm | 05795-31 | ||
3.0 mm I.D. x 100 mm | 05796-21 | ||
3.0 mm I.D. x 150 mm | 05797-11 | ||
3.0 mm I.D. x 250 mm | 05798-01 | ||
4.6 mm I.D. x 30 mm | 05879-41 | ||
4.6 mm I.D. x 50 mm | 34451-21 | ||
4.6 mm I.D. x 100 mm | 05799-91 | ||
4.6 mm I.D. x 150 mm | 02486-71 | ||
4.6 mm I.D. x 250 mm | 02485-81 | ||
6.0 mm I.D. x 150 mm | 34419-61 | ||
6.0 mm I.D. x 250 mm | 05800-41 | ||
10 mm I.D. x 50 mm | 05801-31 | ||
10 mm I.D. x 150 mm | 34466-41 | ||
10 mm I.D. x 250 mm | 34376-21 | ||
20 mm I.D. x 150 mm | 34476-11 | ||
20 mm I.D. x 250 mm | 34373-51 | ||
28 mm I.D. x 250 mm | 34456-71 |
Preparative Column (Particle Size : 15 µm)
COSMOSIL 15C18-PAQ
- For more information on 15C18-PAQ
- Please refer to Inner Diameter of Column(scale down and scale up) (PDF 344 KB)
Analytical Column (Particle Size : 3 µm)
COSMOSIL 3C18-PAQ
Product Name | Size | Product No. | Price |
---|---|---|---|
COSMOSIL 3C18-PAQ Guard Cartridge Guard cartridge holder is required. |
2.0 mm I.D. x 10 mm | 19874-74 | |
4.6 mm I.D. x 10 mm | 19875-64 | ||
COSMOSIL 3C18-PAQ Packed Column | 2.0 mm I.D. x 50 mm | 19773-81 | |
2.0 mm I.D. x 75 mm | 19774-71 | ||
2.0 mm I.D. x 100 mm | 19779-21 | ||
2.0 mm I.D. x 150 mm | 19780-81 | ||
2.0 mm I.D. x 250 mm | 19781-71 | ||
3.0 mm I.D. x 50 mm | 19784-41 | ||
3.0 mm I.D. x 75 mm | 19786-21 | ||
3.0 mm I.D. x 100 mm | 19787-11 | ||
3.0 mm I.D. x 150 mm | 19788-01 | ||
3.0 mm I.D. x 250 mm | 19789-91 | ||
4.6 mm I.D. x 50 mm | 19869-41 | 4.6 mm I.D. x 75 mm | 19870-01 | 4.6 mm I.D. x 100 mm | 19871-91 | 4.6 mm I.D. x 150 mm | 19872-81 | 4.6 mm I.D. x 250 mm | 19873-71 |