COSMOSIL πNAP
Features
- Naphthalene bonded stationary phase
- Enhanced π-π interactions
- Improved selectivity for structural isomers
For information on COSMOSIL 2.5πNAP (Ultra-High Performance Column)
Product Information
Column Specifications
Comparison of π-π interactions
COSMOSIL πNAP shows stronger π-π interactions than phenyl columns. Its two fused aromatic rings retain nitrobenzene with more π electrons stronger than phenyl columns.
Applications
Tolunitrile
Condition | ||
---|---|---|
Column Size | 4.6 mm I.D. x 150 mm | |
Flow Rate | 1.0ml/min | |
Temperature | 30°C | |
Detection | UV 254 nm | |
Sample |
|
Adrenal Cortical Hormone
Condition | ||
---|---|---|
Column Size | 4.6 mm I.D. x 150 mm | |
Flow Rate | 1.0ml/min | |
Temperature | 30°C | |
Detection | UV 254 nm | |
Sample |
|
Berberine
Condition | ||
---|---|---|
Column Size | 4.6 mm I.D. x 150 mm | |
Mobile Phase | Methanol : 20 mmol/l Phosphate Buffer (pH2.5) = 5C18-MS-II 40 : 60 5PE-MS 60 : 40 πNAP 80 : 20 |
|
Flow Rate | 1.0ml/min | |
Temperature | 30°C | |
Detection | UV 254 nm | |
Sample |
|
Isoflavone
Condition | |||
---|---|---|---|
Column Size | 4.6 mm I.D. x 150 mm | Flow rate | 1.0ml/min |
Mobile Phase | A Acetonitrile / 20mmol/l Phosphate Buffer (pH 2.5)=10/90 B Acetonitrile / 20mmol/l Phosphate Buffer (pH 2.5)=50/50 B Conc. 0 → 100% 20min Linear Gradient |
Temperature | 30°C |
Detection | UV 260 nm | ||
Sample |
|
Usage information
Column | 5 µm πNAP | |||||
---|---|---|---|---|---|---|
I.D. (mm) | 2.0 | 3.0 | 4.6 | 10.0 | 20.0 | 28.0 |
Washing method | 1. Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water. 2. (If you used a buffer, always do step 1 first!) Remove adsorbed compounds and fix unstable baselines by washing with methanol and/or THF. |
|||||
Storage conditions | Short-term (up to a week): Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water. Long-term: Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. Then, replace the solvent with 70% methanol or acetonitrile : 30% water. In either case, tightly plug the column, and store in a cool and dry place. |
|||||
Usable pH range | pH2~pH7.5 | |||||
Max. pressure | 20MPa | 15MPa | ||||
Temperature range | The maximum usable temperature is 60°C. However. for regular use, please use at a constant temperature between 20°C and 50°C. | |||||
Usable solvents | Any solvent that will not dissolve the silica gel (such as alkaline solutions) or cleave the stationary phase (such as very acidic solutions) is usable. Note: For solvents with high viscosity, please watch the system pressure and keep it below 20 MPa. Also, please wash the column after using acidic mobile phases or solvents with high freezing points. |
|||||
Other instructions | - Buffer concentration is usually sufficient at 0.005 - 0.02 mol/L. - Always filter mobile phases using a 0.5 µm or finer filter before use. - Acetonitrile is not recommended as a mobile phase. - Baseline drift may occur. |
Downloads
References
Reference list
Ordering Information
Analytical / Preparative Column (Particle Size : 5 µm)
COSMOSIL πNAP
Ultra-High Performance Column (Particle Size : 2.5 µm)
COSMOSIL 2.5πNAP
For information on COSMOSIL 2.5πNAP (Ultra-High Performance Column)
(Storage) RT: Room temperature, A: Cool and dark, R: Refrigerator, F: Freeze