COSMOCORE 2.6Cholester
Features
- Cholesterol-bonded reversed-phase core-shell column
- Usable under the same conditions as C18 columns
- Better selectivity for cis-trans isomers, polyphenols, and natural products
>> Information on COSMOCORE 2.6C18
Product Information
About Core-Shell Particles
Column Specifications
About Core-Shell 2.6Cholester Particles
COSMOCORE 2.6Cholester is packed with cholesterol-bonded 2.6 µm core-shell particles (Figure 1 and 2). It can achieve low pressure compared to fully-porous sub-2 µm columns (Figure 3).
Figure 1: Core-Shell Particle
Figure 2: Bonded Cholestrol Stationary Phase
Figure 3: Comparison of Column Pressure
Column size 2.1mmI.D.-100mm, Mobile Phase Acetonitrile/Water=70/30, Temperature: 40°C
Comparison with C18
COSMOCORE 2.6Cholester offers improved separation for cis-trans isomers than C18 under typical reversed-phase mobile phase.
Condition | ||||
---|---|---|---|---|
Column size | 2.1 mm I.D. - 100 mm | Sample |
|
|
Mobile phase | Methanol | |||
Flow rate | 0.4 ml/min | |||
Temperature | 40°C | Inj. Vol | 0.5µl | |
Detection | UV280nm |
Separation Properties
COSMOCORE 2.6Cholester has about the same hydrophobicity as C18. It is not necessary to change the analytical conditions when replacing C18 Columns with COSMOCORE 2.6Cholester.
Condition | ||||
---|---|---|---|---|
Column size | 2.1 mm I.D. - 100 mm | Sample |
|
|
Mobile phase | Acetonitrile/ H2O = 50/50 | |||
Flow rate | 0.4 ml/min | |||
Temperature | 40°C | |||
Detection | UV254nm | Inj. Vol | 0.25µl |
Molecular Shape Selectivity
COSMOCORE 2.6Cholester has excellent shape slectivity due to its structural rigidity. COSMOCORE 2.6Cholester retains planar triphenylene longer than nonplanar o-Terphenyl.
Condition | ||||
---|---|---|---|---|
Column size | 2.1 mm I.D. - 100 mm | Sample |
|
|
Mobile phase | Acetonitrile/ H2O = 70/30 | |||
Flow rate | 0.4 ml/min | Inj. Vol | 0.5µl | |
Temperature | 40°C | |||
Detection | UV254nm |
Scaling Up from Analytical to Preparative Separation
COSMOCORE 2.6Cholestrer has the same functional group as the fully-porous COSMOSIL Cholester 5 µm silica packing material. Therefore, the separation pattern in COSMOCORE 2.6Cholester is maintained when scaling up to preparative separation with 5 µm COSMOSIL Cholester.
Condition | ||||
---|---|---|---|---|
Mobile phase | Methanol | Sample |
|
|
Flow rate | (2.1mmI.D.) 0.4 ml/min (4.6mmI.D.) 1.0 ml/min (10.0mmI.D.) 5.0 ml/min |
|||
Temperature | 40°C | |||
Detection | UV280nm |
References to COSMOSIL Cholesterol-BondedStationary Phase
The number of COSMOSIL Cholester reference has grown to over 100 since its introduction in 2005. (Reference Search: Google Scholar, as of July 2014)
Figure 1: The number of references to COSMOSIL Cholester and 2.5Cholester
Applications
Separation of natural components (Tomato components)
Lycopene exists in many cis-trans isomers. COSMOCORE 2.6Cholester separates these compounds better than C18.
Condition | Sample preparation | |
---|---|---|
Column size | 3.0mmI.D.-50mm | |
Mobile phase | (2.6C18) Acetonitrile/ H2O = 95/5 (2.6Cholester) Acetonitrile |
|
Flow rate | 1.0 ml/min | |
Temperature | 40°C | |
Detection | UV470nm | |
Sample |
|
|
Inj. Vol | 0.5µl |
Separation of Catechin
Condition | |||
---|---|---|---|
Column Size | 2.1mmI.D.-50mm | Sample |
|
Mobile Phase | A; Acetonitrile/ 0.1% H3PO4 = 10/90 B; Acetonitrile/ 0.1% H3PO4 = 40/60 B conc. 0 - 100% 3min Linear gradient |
||
Flow Rate | 0.6 ml/min | ||
Temperature | 30°C | ||
Detection | UV280nm |
Data courtesy of a customer
Apply to LC/MS
Condition | |||
---|---|---|---|
Column Size | 3.0mmI.D.-50mm | Detection | APCI-MS, Positive, SIM |
Mobile Phase | Acetonitrile | Sample | Tomato extract
|
Flow Rate | 1.0 ml/min | ||
Temperature | 40°C | Inj.Vol. | 0.5µl |
Usage information
Column | 2.6 COSMOCORE Cholester | ||
---|---|---|---|
I.D. (mm) | 2.1 | 3 | 4.6 |
Washing method | 1. Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water. 2. (If you used a buffer, always do step 1 first!) Remove adsorbed compounds and fix unstable baselines by washing with methanol and/or THF. |
||
Storage conditions | Short-term (up to a week): Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water. Long-term: Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. Then, replace the solvent with 70% methanol or acetonitrile : 30% water. In either case, tightly plug the column, and store in a cool and dry place. |
||
Usable pH range | pH 2-7.5 | ||
Max. pressure | 60MPa | ||
Temperature range | The maximum usable temperature is 60°C. However. for regular use, please use at a constant temperature between 20°C and 50°C. | ||
Usable solvents | Any solvent that will not dissolve the silica gel (such as alkaline solutions) or cleave the stationary phase (such as very acidic solutions) is usable. Note: For solvents with high viscosity, please watch the system pressure and keep it below 60 MPa. Also, please wash the column after using acidic mobile phases or solvents with high freezing points. |
||
Other instructions | - Buffer concentration is usually sufficient at 0.005 - 0.02 mol/L. - Always filter mobile phases using a 0.45 µm or finer filter before use. |
Downloads
Brochures
- COSMOCORE Series (5.5 MB)
- COSMOSIL/COSMOCORE Cholester Series Application Notebook and Reference List (14 MB)
Posters
- Identifying vitamins D2/D3 and their 25-OH metabolites and C3 epimers in a single LC-MS run (Poster from HPLC2017 Prague)
(0.3 MB) - Detecting THC Metabolites and other Cannabinoids (Poster from MSACL 2016 US)
(0.3 MB) - A Novel Core-Shell HPLC Column with Unique Shape Selectivity
(Poster from EAS2014, Somerset, NJ USA)
(0.3 MB)
Ordering Information
Analytical Column (Particle size : 2.6 µm)
COSMOCORE 2.6Cholester Column
Product Name | Size | Product No. | Price |
---|---|---|---|
COSMOCORE 2.6Cholester | |||
2.1 mm I.D. x 30 mm | 12858-91 | Inquire Now |
|
2.1 mm I.D. x 50 mm | 12859-81 | ||
2.1 mm I.D. x 75 mm | 12860-41 | ||
2.1 mm I.D. x 100 mm | 12861-31 | ||
2.1 mm I.D. x 150 mm | 12862-21 | ||
3.0 mm I.D. x 30 mm | 12863-11 | ||
3.0 mm I.D. x 50 mm | 12864-01 | ||
3.0 mm I.D. x 75 mm | 12866-81 | ||
3.0 mm I.D. x 100 mm | 12867-71 | ||
3.0 mm I.D. x 150 mm | 12868-61 | ||
4.6 mm I.D. x 30 mm | 12869-51 | ||
4.6 mm I.D. x 50 mm | 12870-11 | ||
4.6 mm I.D. x 75 mm | 12871-01 | ||
4.6 mm I.D. x 100 mm | 12872-91 | ||
4.6 mm I.D. x 150 mm | 12873-81 | ||
4.6 mm I.D. x 250 mm | 12875-61 |
Other sizes may be available.
>> For UHPLC (COSMOCORE) fittings and adapters, please see this page.